Class N - TMQ.C-3850 60L
Class N - TMQ.C-3870 80L
Main properties:
PLC control and touch screen are adopted.
The process of filling water, heating,sterilization,gas exhaust,and drying is
auto controlled by program.
5 sterilizing programs are available.
Temperature and time are displayed dynamically and digitally. A failure display system is equipped.
Speaker will give off signal when the procedure is finished.
Printer can be equipped according to demand.
Environment is kept clean and dry because there are inner cycle systems for water and gas, and it does not need outer water source.
AIDS virus and hepatitis virus can be killed.
autoclave supply |
|
Class B- TMQ.CV-3870 80L
Main properties:
PLC control and touch screen are adopted.
Temperature pressure and time are displayed dynamically and digitally. A failure display system is equipped.
Speaker will give off a signal when the procedure is finished.
Vacuum pump imported from Germany is equipped, vacuum measurement reaches -0.92bar. The air in the clearance of dressing, sterilizing bag and dentist hand device can
be pumped out with 3 grades pre-vacuum.
The high temperature steam can penetrate into the clearance in the porous material(dressing), sterilizing bag, and dentist hand device due to high penetrability.
Pulse behind vacuum drying system, the vacuum can reach -0.92bar and the residue
humidity of instrument after drying will not exceed 0.2%.
4 sterilizing programs and BOWlC & DICK and vacuum test programs are available. 0.2µm bacterium air filter of air after vacuum, re-pollution can be avoided.
Printer is equipped to record the process of sterilization.
AIDS virus and hepatitis virus can be killed.
sterilizer steam autoclave |
|
Class B- TMQ.CVK-2540B 23L
Main properties:
PC control and touch screen are adopted.
Temperature, pressure and time are displayed dynamically and digitally. A failure display system is equipped.
Speaker will give off a signal when the procedure is finished.
Vacuum pump imported from Germany is equipped,vacuum measurement reaches -0.92bar. The air in the clearance of dressing,sterilizing bag
and dentist hand device can be pumped out with 3 grades pre-vacuum.
The high temperature steam can penetrate into the clearance in the porous material (dressing),sterilizing bag,and dentist hand device due to high penetrability.
Pulse behind vacuum drying system, the vacuum can reach -0.92bar,and the residue humidity of instrument after drying will not exceed 0.2%.
4 sterilizing programs and BOWIC & DICK and vacuum test programs are available.
0.2µm bacterium air filter of air after vacuum, re-pollution can be avoided.
Printer can be equipped to record the process of sterilization.
AIDS virus and hepatitis virus can be killed.
Model Chamber Cubage
(L) Chamber Dimension
(mm)(øxL) Outer Dimension(mm)
(LxWxH) Tray Dimension
(mm) Power Consumption
(KW) N.W.
(kgs)
TMQ.CVK-2540B 23 250X440 720X512X440 380X180 2.2(220V) 60
autoclaves supplies |
|
Class S- TMQ.CVK-2540S 23L
Main properties:
PC control and touch screen are adopted.
Temperature, pressure and time are displayed dynamically and digitally. A failure display system is equipped.
Speaker will give off a signal when the procedure is finished.
Vacuum pump imported from Germany is equipped, vacuum measurement reaches -0.7bar. The air in the clearance of dressing, sterilizing bag and dentist hand device can be pumped out with 3 grades pre- vacuum.
The high temperature steam can penetrate into the clearance in the porous material (dressing), sterilizing bag, and dentist hand device due to high penetrability.
Pulse behind vacuum drying system, the vacuum can reach -0.8bar, and the residue humidity of instrument after drying will not exceed 0.2%.
4 sterilizing programs and BOWIC & DICK and vacuum test programs are available. 0.2µm bacterium air filter of air after vacuum, re-pollution can be avoided.
Printer can be equipped to record the process of sterilization.
AIDS virus and hepatitis virus can be killed.
Model Chamber Cubage
(L) Chamber Dimension
(mm)(øxL) Outer Dimension(mm)
(LxWxH) Tray Dimension
(mm) Power Consumption
(KW) N.W.
(kgs)
TMQ.CVK-2540S 23 250X440 720X512X440 380X180 2.2(220V) 60
sterilizer steam autoclaves |
|
Class N - LMQ.R-3260A 50L
Main properties:
The safety of the equipment is guaranteed by an heating auto protection device.
The quick opening pressure safe chain device guarantees the safety of operation.
The safety is guaranteed by safety valve that can decrease the pressure when it is too high.
The process of heating, sterilization, gas exhaust, and drying is auto controlled by program.
Temperatures are displayed dynamically and digitally.
Speaker will give off signal when the procedure is finished.
Environment is kept clean and dry because there are inner cycle systems for water and gas ,and it does not need outer water source.
AIDS virus and hepatitis virus can be killed.
autoclave supply |
|
Class N - LMQ.R-3260B 50L
Main properties:
The safety of the equipment is guaranteed by an heating auto protection device.
The quick opening pressure safe chain device guarantees the safety of operation.
The safety is guaranteed by safety valve that can decrease the pressure when it is too high.
The process of heating, sterilization, gas exhaust, and drying is auto controlled by program.
Temperatures are displayed dynamically and digitally.
Speaker will give off signal when the procedure is finished.
Environment is kept clean and dry because there are inner cycle systems for water and gas, and it does not need outer water source.
AIDS virus and hepatitis virus can be killed.
sterilizer steam autoclave |
|
|