Switch thermal, overload protector, amperage overload protector manufacturer, supplier, factory, exporter--Ningbo Yinzhou Longway Motor Company established in 1985, specialized in manufacturing motors, switch thermal, overload protector, amperage overload protector, switch thermals, overload protectors, amperage overload protectors and thermostats. The company covers an area of more than 12,000 square meters, of which there is a floor area of more than 7,000 square meters. Fixed asset is more than 15 million Yuan. Currently, we have a total of more than 100 staffs, and have 180 sets of main equipments and complete testing equipments. Our products, switch thermal, overload protector, amperage overload protector get a great reputation from the users, with its best quality, reasonable price, and perfect service. It is well sold in the domestic market and most of abroad market. Some of our products, switch thermals, overload protectors, amperage overload protectors have the CE, TUV, UL & CSA, and CCC certificates.

Please visit our website: http://www.ac-gear-motor.com

 
switch thermal
Name: as001

Working Principle:
Normally closed contact system, which is operated by a snap action of bimetal disc, is sensitive to current. When properly applied, protector shuts off the motor or the equipment when temperature exceeds maximum safe level due to an overload or stalled (locked rotor) condition. The greater the work current of motor is, the shorter time the cutting off power needs.
switch thermal
Using Range:
This type Circuit Breaker , overload protector is widely applied to overload protection in Motor, Power Adapter, Combined Outlet, Generator, Battery Charger, Air Compressor etc.

Specification:
Rating Current: 3A~50A
Rating Voltage: AC250V /125V, DC50V; 50~60HZZ
Interrupting Capacity: 1,000Amp*125Vac; 20Amp*250Vac
Dielectric Strength: 1500Vac/1 min
Reset Overload Capacity: 10 times of Rated Current
Voltage Drop: Less than 0.25V
Insulation Resistance: >500M Ω
Temperature Rise at Terminal Black: Less than 65ºC at 100% of Rated Current applied continuously at 25 ºC
Contact Endurance: 125Vac*150% of Rated Current >500 Cycles

Calibration: 25ºC
100% of Rated Current: Hold, No-Trip
150% of Rated Current: Trip in an hour
200% of Rated Current: 5~25 Seconds Trip
300% of Rated Current: 1.5~8 Seconds Trip
400% of Rated Current: 0.75~5 Seconds Trip
500% of Rated Current: 0.5~3 Seconds Trip
600% of Rated Current: 0.4~2 Seconds Trip
800% of Rated Current: 0.3~1.5 Seconds Trip
switch thermals
Details: See details

overload protector
Name: as002

Working Principle:
Normally closed contact system, which is operated by a snap action of bimetal disc, is sensitive to current. When properly applied, protector shuts off the motor or the equipment when temperature exceeds maximum safe level due to an overload or stalled (locked rotor) condition. The greater the work current of motor is, the shorter time the cutting off power needs.
overload protector
Using Range:
This type Circuit Breaker , overload protector is widely applied to overload protection in Motor, Power Adapter, Combined Outlet, Generator, Battery Charger, Air Compressor etc.

Specification:
Rating Current: 3A~50A
Rating Voltage: AC250V /125V, DC50V; 50~60HZZ
Interrupting Capacity: 1,000Amp*125Vac; 20Amp*250Vac
Dielectric Strength: 1500Vac/1 min
Reset Overload Capacity: 10 times of Rated Current
Voltage Drop: Less than 0.25V
Insulation Resistance: >500M Ω
Temperature Rise at Terminal Black: Less than 65ºC at 100% of Rated Current applied continuously at 25ºC
Contact Endurance: 125Vac*150% of Rated Current >500 Cycles

Calibration: 25ºC
100% of Rated Current: Hold, No-Trip
150% of Rated Current: Trip in an hour
200% of Rated Current: 5~25 Seconds Trip
300% of Rated Current: 1.5~8 Seconds Trip
400% of Rated Current: 0.75~5 Seconds Trip
500% of Rated Current: 0.5~3 Seconds Trip
600% of Rated Current: 0.4~2 Seconds Trip
800% of Rated Current: 0.3~1.5 Seconds Trip
overload protectors
Details: See details

amperage overload protector
Name: as003
Sort:
Det

Working Principle:
Normally closed contact system, which is operated by a snap action of bimetal disc, is sensitive to both temperature and current. When properly applied, protector shuts off the motor when temperature exceeds maximum safe level due to an overload or stalled (locked rotor) condition. The greater the work current of motor is, the shorter time the cutting off power needs.
amperage overload protector

Using Range:
This type thermal protector motor protector is widely applied to overheating and overload protection in Motor, Fans, Submersible Pump, Various Pumps, Agricultural Equipment, Air Compressor and Appliances etc.

Specification:
Electrical Ratings: AC380V -----1A~30A
Circuit Control Mode: NC/NO (Automatic Resetting)
Rated Action Temperature: 60ºC ---140ºC (Designed by user's requirements)
Open Tolerance: ±4ºC, ±5 ºC
Open & Close Tolerance: 15 ºC -60 ºC
Close Tolerance:±8 ºC, ±10 ºC
Action Cycle: No less than 10,000 times
Normal Electric Strength: Not Broken within 2000V / 1 minute, No flash.
Normal Isolated Resistance: >100MΩ

Calibration: 25ºC
105% of Rated Current: Hold, >2 hours No-Trip
200% of Rated Current: Within 2 minute Trip
600% of Rated Current: 5~15 Seconds Trip
amperage overload protectors

Deails: See details

more products please visit: http://www.ac-gear-motor.com

Ningbo Yinzhou Longway Motor Company

Address: No.45 West Street, Wuxiang Yinzhou Distric, Ningbo, Zhejiang, China
Zip/Post Code: 315010
Tel: +86-574-87930656
Fax: +86-574-87930655
Web Site: http://www.ac-gear-motor.com
Email: longwaymotor@dc-gear-motor.com
Contact Person: Mr.Weng




 
Home | China Manufacturers Directory | China Products | For Buyer | | Contact Us | Parterships | Sitemap | Friendly Links
© 2003-2009 Deland Web Marketings LLC. All Rights Reserved. Powerby China Products & China Manufacturers