Name: as001
Working Principle:
Normally closed contact system, which is operated by a snap action of bimetal disc, is sensitive to current. When properly applied, protector shuts off the motor or the equipment when temperature exceeds maximum safe level due to an overload or stalled (locked rotor) condition. The greater the work current of motor is, the shorter time the cutting off power needs.
thermal protector
Using Range:
This type Circuit Breaker , overload protector is widely applied to overload protection in Motor, Power Adapter, Combined Outlet, Generator, Battery Charger, Air Compressor etc.
Specification:
Rating Current: 3A~50A
Rating Voltage: AC250V /125V, DC50V; 50~60HZZ
Interrupting Capacity: 1,000Amp*125Vac; 20Amp*250Vac
Dielectric Strength: 1500Vac/1 min
Reset Overload Capacity: 10 times of Rated Current
Voltage Drop: Less than 0.25V
Insulation Resistance: >500M Ω
Temperature Rise at Terminal Black: Less than 65ºC at 100% of Rated Current applied continuously at 25 ºC
Contact Endurance: 125Vac*150% of Rated Current >500 Cycles
Calibration: 25ºC
100% of Rated Current: Hold, No-Trip
150% of Rated Current: Trip in an hour
200% of Rated Current: 5~25 Seconds Trip
300% of Rated Current: 1.5~8 Seconds Trip
400% of Rated Current: 0.75~5 Seconds Trip
500% of Rated Current: 0.5~3 Seconds Trip
600% of Rated Current: 0.4~2 Seconds Trip
800% of Rated Current: 0.3~1.5 Seconds Trip
thermal protectors
Details: See details
|
|
Name: as002
Working Principle:
Normally closed contact system, which is operated by a snap action of bimetal disc, is sensitive to current. When properly applied, protector shuts off the motor or the equipment when temperature exceeds maximum safe level due to an overload or stalled (locked rotor) condition. The greater the work current of motor is, the shorter time the cutting off power needs.
protector thermal
Using Range:
This type Circuit Breaker , overload protector is widely applied to overload protection in Motor, Power Adapter, Combined Outlet, Generator, Battery Charger, Air Compressor etc.
Specification:
Rating Current: 3A~50A
Rating Voltage: AC250V /125V, DC50V; 50~60HZZ
Interrupting Capacity: 1,000Amp*125Vac; 20Amp*250Vac
Dielectric Strength: 1500Vac/1 min
Reset Overload Capacity: 10 times of Rated Current
Voltage Drop: Less than 0.25V
Insulation Resistance: >500M Ω
Temperature Rise at Terminal Black: Less than 65ºC at 100% of Rated Current applied continuously at 25ºC
Contact Endurance: 125Vac*150% of Rated Current >500 Cycles
Calibration: 25ºC
100% of Rated Current: Hold, No-Trip
150% of Rated Current: Trip in an hour
200% of Rated Current: 5~25 Seconds Trip
300% of Rated Current: 1.5~8 Seconds Trip
400% of Rated Current: 0.75~5 Seconds Trip
500% of Rated Current: 0.5~3 Seconds Trip
600% of Rated Current: 0.4~2 Seconds Trip
800% of Rated Current: 0.3~1.5 Seconds Trip
protector thermals
Details: See details
|
|
Name: as003
Sort:
Det
Working Principle:
Normally closed contact system, which is operated by a snap action of bimetal disc, is sensitive to both temperature and current. When properly applied, protector shuts off the motor when temperature exceeds maximum safe level due to an overload or stalled (locked rotor) condition. The greater the work current of motor is, the shorter time the cutting off power needs.
thermal cut-out
Using Range:
This type thermal protector motor protector is widely applied to overheating and overload protection in Motor, Fans, Submersible Pump, Various Pumps, Agricultural Equipment, Air Compressor and Appliances etc.
Specification:
Electrical Ratings: AC380V -----1A~30A
Circuit Control Mode: NC/NO (Automatic Resetting)
Rated Action Temperature: 60ºC ---140ºC (Designed by user's requirements)
Open Tolerance: ±4ºC, ±5 ºC
Open & Close Tolerance: 15 ºC -60 ºC
Close Tolerance:±8 ºC, ±10 ºC
Action Cycle: No less than 10,000 times
Normal Electric Strength: Not Broken within 2000V / 1 minute, No flash.
Normal Isolated Resistance: >100MΩ
Calibration: 25ºC
105% of Rated Current: Hold, >2 hours No-Trip
200% of Rated Current: Within 2 minute Trip
600% of Rated Current: 5~15 Seconds Trip
thermal cut-outs
Deails: See details |
|
|
Ningbo Yinzhou Longway Motor Company
Address: No.45 West Street, Wuxiang Yinzhou Distric, Ningbo, Zhejiang, China
Zip/Post Code: 315010
Tel: +86-574-87930656
Fax: +86-574-87930655 |
|